Toll free 1.888-609-7505

Products:

Heat Trace Cable Data Sheets & Guides

heating cable for medium heat, industrial heating cable used by the heat tracing company

Industrial Heat Trace SR- Self-Regulation Cable: (up to 85℃ / 185℉)

CANSTAL Self-Regulating Heating Cables for all your Pipe Freeze Protection and Roof/Gutter needs. CANSTAL HeatTracer MultiTrace is designed to serve the Commercial, Residential and Industrial non-hazardous markets' demands. This Cable designed to:

- Maintain Temperatures up to 150°F/65°C - Withstand temperatures up to 185°F /85°C - Certified to all applicable CSA (CUS) standards for use throughout North America

industrial heating cables, heat tracing cable, heat tracing company cables

Industrial Heat Trace Warm SR- Self-Regulation Cable: (up to 135℃ / 275℉)

Self-Regulating Heating Cables for all your Pipe Freeze Protection and Roof/Gutter needs. CANSTAL HeatTracer MultiTrace is designed to serve the demands of the Commercial, Residential and Industrial non-hazardous markets. This Cable designed to: - Maintain Temperatures up to 150°F/65°C - Withstand temperatures up to 185°F /85°C - Certified to all applicable CSA (CUS) standards for use throughout North America

high heat tracing cable, for industrial uses, such as oilfield use, heat tracing company

Industrial Heat Trace Hot SR- Self-Regulation Cable: (up to 210℃ / 410℉)

Self-Regulating Heating Cables for all your Pipe Freeze Protection and Roof/Gutter needs. CANSTAL HeatTracer MultiTrace is designed to serve the demands of the Commercial, Residential and Industrial non-hazardous markets. This Cable designed to: - Maintain Temperatures up to 150°F/65°C - Withstand temperatures up to 185°F /85°C - Certified to all applicable CSA (CUS) standards for use throughout North America

high heat tracing cable, for industrial uses, such as oilfield use, heat tracing company

Commercial Heat Trace SR- Self-Regulation Cable: (Fire Sprinkler)

Self-Regulating Heating Cables for all your Pipe Freeze Protection and Roof/Gutter needs. CANSTAL HeatTracer MultiTrace is designed to serve the demands of the Commercial, Residential and Industrial non-hazardous markets. This Cable designed to: - Maintain Temperatures up to 150°F/65°C - Withstand temperatures up to 185°F /85°C - Certified to all applicable CSA (CUS) standards for use throughout North America

medium heat cable, the heating company would use this on gutters and roofs

Residential Heat Trace SR- Self-Regulation Cable: (Gutter & Roof De-icing)

Self-Regulating Heating Cables for all your Pipe Freeze Protection and Roof/Gutter needs. CANSTAL HeatTracer MultiTrace is designed to serve the demands of the Commercial, Residential and Industrial non-hazardous markets. This Cable designed to: - Maintain Temperatures up to 150°F/65°C - Withstand temperatures up to 185°F /85°C - Certified to all applicable CSA (CUS) standards for use throughout North America

pipe heating cable used by heat tracing companies, conductive heating electrical cable

Residential Heat Trace SR- Self-Regulation Cable: (Pipe Heating Cable)

Self-Regulating Heating Cables for all your Pipe Freeze Protection and Roof/Gutter needs. CANSTAL HeatTracer MultiTrace is designed to serve the demands of the Commercial, Residential and Industrial non-hazardous markets. This Cable designed to: - Maintain Temperatures up to 150°F/65°C - Withstand temperatures up to 185°F /85°C - Certified to all applicable CSA (CUS) standards for use throughout North America

constant wattage heating cable, electrical heat tracing cable with glass fiber wrap and stainless steel sheath heating cable

CW- Constant-Wattage Heating Cable

CONSTANT-WATTAGE, METALLIC-SHEATHED, HIGH-TEMPERATURE HEATING CABLE - CMH is a cut-to-length, constant wattage heater engineered for high-temperature trace heating applications (842°F/450°C). Intended as a replacement for series type Mineral Insulated (MI) cable, the design features of PipeGuard CMH make it a clear choice for freeze protection or process temperature maintenance on metal pipes and vessels in ordinary and hazardous electrical areas.

copper heating conductor cable, heat tracing cable with HDPE Jacket

MI - MINERAL INSULATED Heating Cable​

Mineral Insulated (MI) copper heating cables are ideal for embedded applications, such as snow melting in concrete or asphalt slabs. Designed to yield up to a maximum of 30 watts per linear foot of cable,  -Single and Dual conductor cables available

Temperature Controllers

Single-Circuit Controllers

Dual-Circuit Controllers

Multi-Circuit Controllers

Heat Trace Thermostat Sensors

thermostat to measure heat, the heat tracing company to install and check the thermostat

STAT-TXR-ADJ Thermostat​

The STAT-TXR-ADJ thermostat is ideal for applications where freeze protection or temperature control in hazardous locations is critical. This thermostat can be used in ambient-sensing applications by placing the sensor in the air or as a line-sensing thermostat by securing the bulb to the pipe or tank. The STAT-TXR-ADJ can be used as a single circuit control or as a pilot control for several circuits by switching a contactor.

heat tracing thermostat, used to detect and regulate temperature, usually installed by the heat tracing company

STAT-LS-40F Thermostat

The STAT-LS-40F thermostat is ideal for applications where freeze protection or lower-range temperature control is critical. In cold climates, the thermostat switches heating devices that prevent pipes, valves, tanks and fittings from freezing. This thermostat can be used in ambient-sensing applications by placing the sensor in the air or as a line-sensing thermostat by securing the bulb to the pipe or tank. It can be used as a single circuit control or as a pilot control for several circuits by switching a contactor. The setpoint at the factory is 40°F/5°C.

Heat Trace Insulation Product

FQA

Self-Regulating Heating Cable (SR) is a selfregulating heating cable that provides maximum freeze protection for pipelines and vessels. The selfregulating heating cable automatically varies its heat output as the surrounding temperature changes.

Trace heating is that the application of a controlled quantity of electrical surface heating to pipes, tanks, valves, or process instrumentation to either maintain its temperature (by replacement the heat lost through insulation, additionally remarked as frost protection) or to AN effect on} a rise in its temperature – this can be done by using heating cables normally named as heat trace or heat trace self-regulating heat tracing cables have an improved level of inherent potency increased as hyperbolic safety if its application is properly thought of. Beginning with the previous, at higher temperatures, the heating cable backs off its output, saving power even though not connected via a controller or thermostat.
This is not to say it’ll hold a set target temperature while not external control. However, the reduction of output is a fascinating feature from an associate energy conservation perspective because the work-piece temperature will increase.
This also offers rise to a different, extremely fascinating characteristic of self-acting cables, which can assign a T category (temperature rating) for ATEX functions and safe installation in hazardous area locations. With the decrease in power output, because the cable temperature will increase, it’s unacceptable for the cable to affect a rise to a temperature on the far side at an explicit level, notwithstanding the amount of thermal insulation used.

EHT power kit CANSTAL

The power connection kit is suitable for use only with the series heating cables. The package provides material for one power connection.

There are three recommended methods of heat tracing control Sensor:

  • Manual Control: MultiTrace switched manually. This method requires supervision to work effectively.
  • Ambient Control: using an ambient thermostat ensures that when the temperature is below freezing, the MultiTrace becomes energized. With this method, you must recognize that even when no snow/ice is present the cables may become energized and power consumed.
  • Automatic Control: this method ensures that MultiTrace energized only when a combination of moisture and low temperature are present, thereby keeping the pipes free of snow/ice. When either the precipitation ceases, or the temperature rises above freezing the MultiTrace is turned off thus conserving energy.

Free Quote: